Service — Statewide Lehigh Valley

Engineering & Permitting in the Lehigh Valley

Lehigh Valley Pallet Racking provides complete engineering and permitting services for racking projects throughout Allentown, PA and the broader Lehigh Valley.

Pallet racking engineering drawings and permit documentation for Lehigh Valley warehouses
OSHA-COMPLIANT — Engineering & Permitting

Engineering & Permitting for warehouses across the Lehigh Valley. Free, no-obligation estimates.

// Overview

Engineering & Permitting in the Lehigh Valley

Lehigh Valley Pallet Racking provides complete engineering and permitting services for racking projects throughout Allentown, PA and the broader Lehigh Valley. Our engineering work — performed in partnership with licensed structural engineers — produces stamped drawings, seismic load calculations, wind-load analyses, and permit-ready documentation packages that meet Pennsylvania Uniform Construction Code requirements. We then take that documentation directly to the appropriate building authority across any of the 12 Lehigh Valley jurisdictions we serve, manage the entire permit application process, respond to plan review comments, and track your permit through to issuance.

  • Obtain permits faster with complete, professional documentation packages
  • Ensure your racking meets all Lehigh Valley structural and building codes
  • Avoid costly permit mistakes and project delays from incorrect submissions
  • Maintain focus on your core business while we handle the engineering and paperwork
Warehouse worker in a racked pallet aisle
Industrial metal shelving and racking in a warehouse

// What's included

What you get

  • Licensed PE stamped CAD drawings
  • Seismic and wind load calcs per Pennsylvania Uniform Construction Code
  • Permit application preparation and submission
  • Plan-review response and permit tracking to issuance

// How it works

The process

01

Facility Analysis & System Design

We gather floor plans, slab specs, ceiling heights, inventory weights, and forklift dimensions — then develop optimized rack layouts that maximize storage density while maintaining required safety clearances.

02

Structural Calculations & Stamped Drawings

Licensed engineers perform all required structural calculations, including seismic analysis and Lehigh Valley wind-load per applicable code, and produce stamped CAD drawings suitable for building permit submission.

03

Permit Application & Submission

We identify the correct building authority for your project location across the Lehigh Valley, prepare all required submittal documents, and submit your permit application on your behalf.

// Warning signs

Signs You Need Stamped Engineering & Permit Support

  • Project scope exceeds IFC Chapter 32 threshold (8 ft top of load or storing Group A plastics) — standard for tall-clear Valley distribution warehouses
  • Building department in Allentown, Easton, Bethlehem, or any Lehigh Valley jurisdiction has rejected or requested revisions on your submittal
  • Manufacturer-stamped drawings were rejected because they were not sealed by a licensed Pennsylvania PE
  • Post-tension slab — anchor location and depth must be engineered around cable mapping
  • Lehigh Valley wind exposure was not accounted for in original calcs
  • Wetland proximity or FEMA flood zone requires modified base-plate and anchor design
  • Corporate risk/insurance requires a wet-stamped structural package on file
Certified crew installing pallet racking in a Lehigh Valley warehouse

// Straight answers

Engineering & Permitting questions

01

Do I need a licensed engineer's stamp for rack in the Lehigh Valley?

Yes for most Lehigh Valley jurisdictions. Allentown, Bethlehem, Easton and the townships and boroughs across Lehigh and Northampton counties all require a licensed Pennsylvania PE stamp on rack drawings above threshold height or specified PSF. Self-submission is sometimes accepted for very small under-threshold installs in smaller municipalities, but rejection risk is high without a stamp and the resubmittal delay usually erases any savings.

02

How long does rack permit review take in the Lehigh Valley area?

Lehigh County and City of Easton typically run 2–4 weeks on initial review. City of Allentown typically runs 3–5 weeks, with high-piled storage projects sometimes longer due to fire suppression coordination. the Slate Belt and smaller Lehigh Valley municipalities are typically the fastest at 2–4 weeks. We build these timelines into the project schedule and manage plan review comments actively to avoid resubmittal loops.

03

What is included in your engineering package?

A full package: rack elevation and plan drawings, anchor details with concrete strength assumptions, seismic and wind-load calcs per IBC as adopted by the Pennsylvania Uniform Construction Code, in-rack sprinkler clearances per NFPA 13, column protection specifications, and rated load placards. For high-piled storage we add IFC Chapter 32 analysis with commodity classification — standard for high-piled storage and defense-supply warehouses throughout the Lehigh Valley.

04

Which Lehigh Valley jurisdictions have you permitted rack in?

Active experience submitting to the City of Allentown Bureau of Building Standards and Safety, the municipal building code office, City of Easton Bureau of Codes and Inspections, City of Bethlehem Bureau of Code Enforcement, the Northampton County township code offices, the Slate Belt borough code offices, and other Lehigh Valley county and municipal agencies. Every jurisdiction has specific submittal quirks — we pre-format packages to match.

05

How much do rack permits and engineering cost in the Lehigh Valley?

Budget roughly $1,500–$3,500 for stamped engineering calculations and drawings on a typical Lehigh Valley rack project, plus municipal permit fees that vary by jurisdiction. Lehigh Valley Pallet Racking bundles the engineering, high-piled storage review, and permit submittal into one package and submits them concurrently, keeping most plan reviews to three to six weeks.

06

Can I install pallet racking without a permit in the Lehigh Valley?

Not legally for most systems — every Lehigh Valley jurisdiction requires a building permit for rack over 8 feet tall, and storage above 12 feet triggers fire-code high-piled storage review. Unpermitted rack risks stop-work orders, insurance denial after an incident, and forced tear-outs. Lehigh Valley Pallet Racking handles the entire permitting process so installations are inspection-ready from day one.

// Ready when you are

Need Engineering & Permitting